1.1. What Is GATE?
Table of Contents
GATE and Geant4
GATE is a software framework that allows you to simulate how particles, such as photons, electrons, and protons, interact with matter in medical physics scenarios. It is built on top of Geant4, which is a general-purpose Monte Carlo particle transport toolkit originally developed for high-energy physics.
Geant4 provides the core physics engine. It knows how particles move, scatter, lose energy, and produce secondary particles as they pass through materials. It also provides tools for defining geometry, materials, and physics models. However, using Geant4 directly usually requires writing C++ code and manually handling many low-level details.
GATE sits on top of Geant4 and offers a more convenient environment tailored for medical physics and nuclear imaging. In modern OpenGATE, you use Python to describe your simulation. GATE translates your geometry, materials, sources, and scoring setup into appropriate Geant4 configurations and then runs the simulation using the Geant4 engine.
You can think of GATE and Geant4 as working together as follows:
GATE focuses on medical applications such as PET, SPECT, CT, radiotherapy, proton therapy, dosimetry, and detector development. It provides high-level concepts that are familiar to medical physicists, like dose actors, PET events, or voxelized patient geometries.
Geant4 handles particle tracking, physics interactions, low-level geometry navigation, and random sampling. All detailed physics models and transport processes come from Geant4.
Because of this structure, learning GATE does not mean you must become an expert C++ Geant4 programmer. Instead, you learn how to control Geant4 through GATE, using Python and medical-physics oriented tools. Whenever you see GATE run a simulation, it is Geant4 that actually transports particles, but everything is configured, controlled, and analyzed in GATE.
Monte Carlo simulation in medical physics
GATE uses Monte Carlo simulation to model radiation transport. In Monte Carlo methods, random numbers are used to sample physical processes. Each simulated particle follows a random path according to the probabilities of interaction given by the physics models.
In medical physics, this approach is valuable because radiation transport in tissue or detectors is highly complex. Analytical formulas are often approximate or limited to simple geometries. Monte Carlo can handle complex patient anatomy, detailed detector structures, and realistic energy spectra.
At a basic level, a Monte Carlo transport step in GATE and Geant4 consists of:
Randomly sampling the free path length until the next interaction, based on the interaction cross sections in the given material.
Choosing which process happens at that interaction, for example Compton scattering, photoelectric absorption, or pair production, according to their relative probabilities.
Sampling the kinematics of the interaction, such as scattering angle and energy loss, from differential cross sections.
Repeating these steps until the particle leaves the geometry, loses all its energy, or is terminated by a cut.
Because each particle history is different, Monte Carlo simulations require many particles in order to obtain stable statistical results. Statistical uncertainty in a quantity such as dose or detector counts usually scales approximately as $1 / \sqrt{N}$, where $N$ is the number of histories. This means that to reduce the relative uncertainty by a factor of 2 you need about 4 times more histories.
Key idea: Monte Carlo simulations in GATE track individual particle histories using random sampling of interaction processes and path lengths. Results converge statistically as the number of simulated histories increases, with uncertainty roughly proportional to $1 / \sqrt{N}$.
In medical physics, Monte Carlo simulations are particularly important when precision is needed, such as in dose calculations for complex treatments, or when you need detailed modeling of detector response, scatter, and attenuation.
Medical imaging simulation
GATE is widely used to simulate medical imaging systems that detect photons from radioactive tracers or X-ray sources. For emission tomography, such as PET and SPECT, patients are injected with a radiotracer that emits gamma rays. For transmission imaging, such as CT, an external X-ray source illuminates the patient and detectors measure the transmitted photons.
In all these cases, GATE can represent the imaging system geometry, the physics of photon transport, and the detector response. You describe the scanner, for instance a PET ring or a SPECT gamma camera, and specify the radioactive source or X-ray beam. GATE then simulates how photons are emitted, how they travel through the patient or phantom, how they are attenuated or scattered, and finally how they interact in detector crystals.
For emission imaging, GATE allows you to set up realistic activity distributions that represent how a tracer is taken up in tissues. You can model spatially uniform sources or complex voxel-based sources derived from medical images. The simulation tracks emitted photons, their interactions in the body, and their eventual detection. This is essential for understanding system sensitivity, scatter fraction, randoms, and image quality.
For CT and X-ray imaging, GATE can simulate a moving X-ray source and a detector array around a phantom or patient model. It records transmitted photons and creates projection data, which can be compared to reconstructed CT images or used to test new detector designs.
In all of these imaging applications, Monte Carlo simulation with GATE provides a way to study effects that are hard to isolate experimentally, such as the contribution of scattered photons to a particular region of the image, or the effect of changing detector materials or geometry on resolution and sensitivity.
Radiation therapy simulation
In radiation therapy, high-energy photon, electron, or proton beams are used to deliver dose to tumors while sparing healthy tissue. GATE can model this process by simulating the transport of therapeutic beams through treatment machines and patients or phantoms.
At the most basic level, you specify the beam, for example a photon beam with a certain energy spectrum and field size, or a proton beam with a defined energy and spot size. You then define the geometry representing the treatment head, collimators, and patient or phantom.
GATE uses Geant4 physics to simulate how the therapeutic particles lose energy, scatter, and produce secondary particles as they pass through materials. This includes build-up effects in photon beams, multiple scattering of electrons, and the characteristic depth-dose behavior of protons.
Because it is based on detailed particle transport, GATE can handle complex geometries, such as multi-leaf collimators, non-uniform patient anatomy, and heterogeneous tissues. This is especially important when beam paths intersect regions of very different densities or compositions, where simple dose calculation algorithms may be inaccurate.
In radiotherapy simulation, GATE is often used to:
Model and validate treatment machine components.
Investigate the impact of beam modifiers such as wedges or compensators.
Study advanced techniques such as intensity-modulated radiotherapy or arc therapies, when combined with time-dependent or moving geometries.
Provide reference Monte Carlo dose distributions that can be compared with clinical treatment planning system calculations.
Because treatment accuracy is critical, Monte Carlo simulations with GATE are frequently used as a high-fidelity standard for benchmarking and research, even when they are too slow for routine clinical use.
Radiation dosimetry
Radiation dosimetry concerns the measurement and calculation of dose, which is the energy deposited per unit mass of material. It is a central concept in both imaging, where you want to understand and minimize patient dose, and therapy, where you must ensure the prescribed dose is delivered accurately.
In GATE, dose is typically obtained by simulating the energy deposition of particles inside defined scoring volumes, which can be simple geometric regions, phantoms, or voxelized patient geometries. GATE includes dedicated dose actors that accumulate the deposited energy in each volume element, then convert it to absorbed dose, usually measured in gray, where $1 \, \text{Gy} = 1 \, \text{J} / \text{kg}$.
The basic relation between deposited energy $E$ and dose $D$ in a volume of mass $m$ is:
$$
D = \frac{E}{m}.
$$
Important relation: The absorbed dose $D$ in a volume is given by $D = E / m$, where $E$ is the total energy deposited in joules and $m$ is the mass of the volume in kilograms. The SI unit of dose is the gray, defined as $1 \, \text{Gy} = 1 \, \text{J} / \text{kg}$.
GATE allows you to compute dose distributions at different levels of detail. For simple phantoms you might record mean dose in a few regions. For more realistic studies you can set up a voxel grid and obtain a 3D dose map. This is useful to visualize hot and cold spots, compare different treatment plans, or evaluate dose to specific organs.
In internal dosimetry, which concerns dose from radionuclides inside the body, GATE can simulate decays over time, track emissions of beta particles and photons, and record the spatial pattern of energy deposition. This provides organ dose or voxel-based dose maps for radionuclide therapies, which is important for treatment planning and risk assessment.
Statistical uncertainty is always present in Monte Carlo dosimetry. Dose in voxels with few interactions may have large relative errors. You can reduce this by increasing the number of simulated histories or by adjusting the voxel size, always balancing accuracy and computation time.
Detector simulation
Detectors are at the heart of both medical imaging and radiation measurement. GATE provides tools to model detector geometries, materials, and signal formation so that you can study and optimize detector performance.
On the physical side, GATE uses Geant4 to simulate how particles interact within the detector materials. For example, in a scintillation detector, gamma rays may undergo photoelectric absorption or Compton scattering in the crystal, producing energetic electrons. These electrons then deposit energy in the material. GATE can record these energy deposits and their positions and times as hits.
Beyond recording hits, detector simulation in GATE often includes digitization, which is the transformation of physical interactions into measurable electronic signals. This can include steps such as:
Grouping multiple energy deposits in a crystal to form a single detector event.
Adding energy blurring to model finite energy resolution.
Applying timing blurring to simulate timing resolution.
Enforcing energy thresholds and windows to reject low-energy or out-of-window events.
Identifying detector elements through IDs, such as which crystal module or pixel was hit.
Through these features, GATE can simulate realistic detector outputs such as singles and coincidence events in PET, projection data in SPECT, or pixel signals in X-ray and CT detectors. This allows you to study how changes in detector geometry, material, or electronics affect energy spectra, spatial resolution, sensitivity, and noise.
Detector simulation is also essential for designing new systems. Before building a prototype, you can use GATE to predict how a new scintillator, a different crystal size, or a new collimator geometry will influence performance. Because GATE is linked to detailed physics, it can capture effects that simpler analytical models cannot, such as the full spectrum of scattered events, or intricate geometrical effects in multi-layer detectors.
Altogether, GATE provides a bridge between fundamental particle transport with Geant4 and the practical questions of medical physics: how to design detectors and scanners, how to deliver dose accurately, and how to understand and improve the images and measurements used in patient care.
Views: 0
Where to Move
Move chapter:
- ☰ 1. Introduction to GATE
- ☰ 1.1. What Is GATE?
- ☰ 1.2. Applications of GATE
- ☰ 1.3. GATE vs Geant4
- ☰ 1.4. GATE Simulation Workflow
-
- ☰ 2. Installing GATE
- ☰ 2.1. GATE Requirements
- ☰ 2.2. Creating a Python Environment
- ☰ 2.3. Installing GATE
- ☰ 2.4. Verifying the Installation
- ☰ 2.5. GATE Example Simulations
-
- ☰ 3. Python Basics for GATE
- ☰ 3.1. Variables and Data Types
- ☰ 3.2. Conditional Statements
- ☰ 3.3. Loops
- ☰ 3.4. Functions
- ☰ 3.5. Python Modules
- ☰ 3.6. NumPy Basics
- ☰ 3.7. Working with Files
-
- ☰ 4. Creating Your First GATE Simulation
- ☰ 4.1. Importing GATE
- ☰ 4.2. Creating a Simulation
- ☰ 4.3. Adding the World
- ☰ 4.4. Adding a Particle Source
- ☰ 4.5. Adding an Actor
- ☰ 4.6. Running the Simulation
- ☰ 4.7. Inspecting the Results
-
- ☰ 5. Units in GATE
- ☰ 5.1. Physical Units
- ☰ 5.2. Length Units
- ☰ 5.3. Energy Units
- ☰ 5.4. Time Units
- ☰ 5.5. Radioactivity Units
- ☰ 5.6. Using Units Correctly
-
- ☰ 6. Geometry Fundamentals
- ☰ 6.1. The World Volume
- ☰ 6.2. Creating Volumes
- ☰ 6.3. Box Geometry
- ☰ 6.4. Cylindrical Geometry
- ☰ 6.5. Spherical Geometry
- ☰ 6.6. Position and Translation
- ☰ 6.7. Rotation
-
- ☰ 7. Building Complex Geometry
- ☰ 7.1. Nested Volumes
- ☰ 7.2. Repeated Volumes
- ☰ 7.3. Ring Geometry
- ☰ 7.4. Boolean Geometry
- ☰ 7.5. Geometry Overlap
- ☰ 7.6. Reusable Geometry Functions
-
- ☰ 8. Materials
- ☰ 8.1. Material Definitions
- ☰ 8.2. Geant4 Material Database
- ☰ 8.3. Common Medical Materials
- ☰ 8.4. Detector Materials
- ☰ 8.5. Shielding Materials
- ☰ 8.6. Creating Custom Materials
-
- ☰ 9. Geometry Visualization
- ☰ 9.1. Enabling Visualization
- ☰ 9.2. Displaying Volumes
- ☰ 9.3. Changing the View
- ☰ 9.4. Volume Appearance
- ☰ 9.5. Visualizing Particle Tracks
- ☰ 9.6. Debugging with Visualization
-
- ☰ 10. Particle Sources
- ☰ 10.1. Generic Sources
- ☰ 10.2. Particle Types
- ☰ 10.3. Source Position
- ☰ 10.4. Source Direction
- ☰ 10.5. Source Energy
- ☰ 10.6. Source Activity
-
- ☰ 11. Radioactive Sources
- ☰ 11.1. Radioactive Decay
- ☰ 11.2. Medical Radionuclides
- ☰ 11.3. Positron Emitters
- ☰ 11.4. Gamma Emitters
- ☰ 11.5. Activity Distribution
- ☰ 11.6. Time-Dependent Activity
-
- ☰ 12. Physics Lists
- ☰ 12.1. What Is a Physics List?
- ☰ 12.2. Electromagnetic Physics
- ☰ 12.3. Gamma Physics
- ☰ 12.4. Electron Physics
- ☰ 12.5. Positron Physics
- ☰ 12.6. Hadronic Physics
- ☰ 12.7. Choosing Physics Models
-
- ☰ 13. Production Cuts and Transport Parameters
- ☰ 13.1. What Are Production Cuts?
- ☰ 13.2. Range Cuts
- ☰ 13.3. Region-Based Cuts
- ☰ 13.4. Accuracy vs Performance
-
- ☰ 14. Actors
- ☰ 14.1. What Is an Actor?
- ☰ 14.2. Simulation Statistics Actor
- ☰ 14.3. Energy Deposition Actor
- ☰ 14.4. Dose Actor
- ☰ 14.5. Phase Space Actor
- ☰ 14.6. Particle Fluence
- ☰ 14.7. Actor Filters
-
- ☰ 15. Dose Calculation
- ☰ 15.1. Energy Deposition
- ☰ 15.2. Absorbed Dose
- ☰ 15.3. Creating a Dose Actor
- ☰ 15.4. Dose Images
- ☰ 15.5. Statistical Uncertainty
- ☰ 15.6. Dose Profiles
-
- ☰ 16. Hits and Detector Response
- ☰ 16.1. Particle Interactions in Detectors
- ☰ 16.2. Hits
- ☰ 16.3. Hit Collections
- ☰ 16.4. Hit Attributes
- ☰ 16.5. Hits vs Detector Signals
-
- ☰ 17. Digitizers
- ☰ 17.1. What Is Digitization?
- ☰ 17.2. Digitizer Chain
- ☰ 17.3. Energy Summation
- ☰ 17.4. Readout
- ☰ 17.5. Energy Blurring
- ☰ 17.6. Spatial Blurring
- ☰ 17.7. Energy Thresholds
- ☰ 17.8. Time Blurring
-
- ☰ 18. Singles
- ☰ 18.1. What Are Singles?
- ☰ 18.2. Creating Singles
- ☰ 18.3. Detector Identification
- ☰ 18.4. Energy Windows
- ☰ 18.5. Analyzing Singles
-
- ☰ 19. Coincidences
- ☰ 19.1. What Are Coincidences?
- ☰ 19.2. Coincidence Sorting
- ☰ 19.3. True Coincidences
- ☰ 19.4. Scattered Coincidences
- ☰ 19.5. Random Coincidences
- ☰ 19.6. Coincidence Timing
- ☰ 19.7. Coincidence Output
-
- ☰ 20. Data Output
- ☰ 20.1. Simulation Output
- ☰ 20.2. ROOT Output
- ☰ 20.3. Image Output
- ☰ 20.4. Text-Based Output
- ☰ 20.5. Organizing Simulation Results
-
- ☰ 21. GATE and ROOT
- ☰ 21.1. Reading GATE ROOT Files
- ☰ 21.2. Inspecting Output
- ☰ 21.3. Energy Histograms
- ☰ 21.4. Time Histograms
- ☰ 21.5. Detector Maps
- ☰ 21.6. Filtering Events
-
- ☰ 22. GATE and Python Data Analysis
- ☰ 22.1. Reading Simulation Output with Python
- ☰ 22.2. Energy Spectra
- ☰ 22.3. Position Distributions
- ☰ 22.4. Timing Analysis
- ☰ 22.5. Statistical Analysis
- ☰ 22.6. Visualization
-
- ☰ 23. Voxelized Geometry
- ☰ 23.1. Introduction to Voxelized Geometry
- ☰ 23.2. Image-Based Volumes
- ☰ 23.3. Material Mapping
- ☰ 23.4. CT-to-Material Conversion
- ☰ 23.5. Patient Geometry
- ☰ 23.6. Visualizing Voxelized Geometry
-
- ☰ 24. Image and DICOM Data
- ☰ 24.1. Medical Image Formats
- ☰ 24.2. Reading CT Images
- ☰ 24.3. DICOM CT Data
- ☰ 24.4. RT Structure Sets
- ☰ 24.5. RT Plans
- ☰ 24.6. Coordinate Systems
-
- ☰ 25. Motion and Time-Dependent Simulations
- ☰ 25.1. Time in GATE
- ☰ 25.2. Moving Sources
- ☰ 25.3. Moving Detectors
- ☰ 25.4. Respiratory Motion
- ☰ 25.5. Scanner Rotation
- ☰ 25.6. Dynamic Imaging
-
- ☰ 26. PET Simulation Fundamentals
- ☰ 26.1. PET Physics
- ☰ 26.2. PET Scanner Components
- ☰ 26.3. PET Detector Geometry
- ☰ 26.4. PET Source
- ☰ 26.5. PET Physics Configuration
- ☰ 26.6. PET Detector Response
-
- ☰ 27. Building a PET Scanner
- ☰ 27.1. Creating the Detector Ring
- ☰ 27.2. Creating Detector Blocks
- ☰ 27.3. Creating Detector Crystals
- ☰ 27.4. Assigning Detector IDs
- ☰ 27.5. Adding a PET Source
- ☰ 27.6. Configuring the Digitizer
- ☰ 27.7. Running the PET Simulation
-
- ☰ 28. PET Coincidence Analysis
- ☰ 28.1. Coincidence Events
- ☰ 28.2. Energy Selection
- ☰ 28.3. Coincidence Time Window
- ☰ 28.4. Lines of Response
- ☰ 28.5. True Events
- ☰ 28.6. Scatter Events
- ☰ 28.7. Random Events
- ☰ 28.8. PET Performance Metrics
-
- ☰ 29. Time-of-Flight PET
- ☰ 29.1. TOF PET Principles
- ☰ 29.2. Detector Timing Resolution
- ☰ 29.3. Time Difference
- ☰ 29.4. Timing Blurring
- ☰ 29.5. Analyzing TOF Events
-
- ☰ 30. SPECT Simulation Fundamentals
- ☰ 30.1. SPECT Physics
- ☰ 30.2. SPECT Scanner Components
- ☰ 30.3. SPECT Radionuclides
- ☰ 30.4. Gamma Camera Geometry
- ☰ 30.5. SPECT Source
-
- ☰ 31. Building a Gamma Camera
- ☰ 31.1. Detector Head
- ☰ 31.2. Collimator
- ☰ 31.3. Shielding
- ☰ 31.4. Energy Resolution
- ☰ 31.5. Energy Window
- ☰ 31.6. Projection Data
-
- ☰ 32. SPECT Acquisition
- ☰ 32.1. Rotating Gamma Camera
- ☰ 32.2. Projection Angles
- ☰ 32.3. Acquisition Time
- ☰ 32.4. Energy Windows
- ☰ 32.5. Projection Images
- ☰ 32.6. SPECT Data Analysis
-
- ☰ 33. CT and X-Ray Simulation
- ☰ 33.1. X-Ray Physics
- ☰ 33.2. X-Ray Source
- ☰ 33.3. CT Geometry
- ☰ 33.4. Detector Array
- ☰ 33.5. Rotating CT Geometry
- ☰ 33.6. CT Projection Data
-
- ☰ 34. Radiation Therapy Simulation
- ☰ 34.1. External Beam Radiotherapy
- ☰ 34.2. Photon Beams
- ☰ 34.3. Electron Beams
- ☰ 34.4. Dose Calculation
- ☰ 34.5. Beam Geometry
- ☰ 34.6. Dose Validation
-
- ☰ 35. Proton Therapy Simulation
- ☰ 35.1. Proton Physics
- ☰ 35.2. Proton Beam
- ☰ 35.3. Water Phantom
- ☰ 35.4. Bragg Peak
- ☰ 35.5. Spread-Out Bragg Peak
- ☰ 35.6. Proton Dose Analysis
-
- ☰ 36. Internal Dosimetry
- ☰ 36.1. Radioactive Sources in the Body
- ☰ 36.2. Voxelized Activity Maps
- ☰ 36.3. Energy Deposition
- ☰ 36.4. Dose Maps
- ☰ 36.5. Radionuclide Therapy
- ☰ 36.6. Dose Analysis
-
- ☰ 37. Optical Photon Simulation
- ☰ 37.1. Optical Physics
- ☰ 37.2. Scintillation
- ☰ 37.3. Optical Properties
- ☰ 37.4. Optical Surfaces
- ☰ 37.5. Photodetectors
- ☰ 37.6. Optical Photon Detection
-
- ☰ 38. Phase-Space Data
- ☰ 38.1. What Is a Phase Space?
- ☰ 38.2. Recording Phase-Space Data
- ☰ 38.3. Phase-Space Files
- ☰ 38.4. Phase-Space Sources
- ☰ 38.5. Applications
-
- ☰ 39. Random Numbers and Reproducibility
- ☰ 39.1. Monte Carlo Random Numbers
- ☰ 39.2. Random Seeds
- ☰ 39.3. Independent Simulations
- ☰ 39.4. Reproducible Research
-
- ☰ 40. Multithreading and Performance
- ☰ 40.1. Multithreaded Simulation
- ☰ 40.2. Selecting the Number of Threads
- ☰ 40.3. Simulation Speed
- ☰ 40.4. Optimizing Geometry
- ☰ 40.5. Optimizing Output
- ☰ 40.6. Large Simulations
-
- ☰ 41. Running GATE on HPC Systems
- ☰ 41.1. Why Use HPC?
- ☰ 41.2. Running GATE Without Visualization
- ☰ 41.3. Job Scripts
- ☰ 41.4. Running with Slurm
- ☰ 41.5. Running Multiple Simulations
- ☰ 41.6. Combining Results
-
- ☰ 42. Simulation Validation
- ☰ 42.1. Why Validate a GATE Simulation?
- ☰ 42.2. Geometry Validation
- ☰ 42.3. Physics Validation
- ☰ 42.4. Comparing with Analytical Models
- ☰ 42.5. Comparing with Experimental Data
- ☰ 42.6. Statistical Validation
-
- ☰ 43. Debugging GATE Simulations
- ☰ 43.1. Python Errors
- ☰ 43.2. Geometry Problems
- ☰ 43.3. Material Errors
- ☰ 43.4. Source Problems
- ☰ 43.5. Physics Problems
- ☰ 43.6. Actor Problems
- ☰ 43.7. Digitizer Problems
- ☰ 43.8. Performance Problems
-
- ☰ 44. Writing Better GATE Simulations
- ☰ 44.1. Organizing Simulation Scripts
- ☰ 44.2. Configuration Files
- ☰ 44.3. Avoiding Hard-Coded Values
- ☰ 44.4. Reusable Components
- ☰ 44.5. Output Organization
- ☰ 44.6. Documentation
- ☰ 44.7. Version Control
-
- ☰ 45. Practical Example: Gamma-Ray Detector
- ☰ 45.1. Project Overview
- ☰ 45.2. Creating the World
- ☰ 45.3. Creating the Detector
- ☰ 45.4. Creating a Gamma Source
- ☰ 45.5. Configuring Electromagnetic Physics
- ☰ 45.6. Recording Energy Deposition
- ☰ 45.7. Adding Energy Resolution
- ☰ 45.8. Creating an Energy Spectrum
- ☰ 45.9. Analyzing the Spectrum
-
- ☰ 46. Practical Example: Radiation Shielding
- ☰ 46.1. Project Overview
- ☰ 46.2. Creating the Source
- ☰ 46.3. Creating the Shield
- ☰ 46.4. Selecting Shielding Materials
- ☰ 46.5. Changing Shield Thickness
- ☰ 46.6. Recording Transmitted Photons
- ☰ 46.7. Calculating Transmission
- ☰ 46.8. Calculating Attenuation
- ☰ 46.9. Comparing with the Exponential Attenuation Law
-
- ☰ 47. Practical Example: PET Scanner
- ☰ 47.1. Project Overview
- ☰ 47.2. Creating the PET Ring
- ☰ 47.3. Creating Detector Modules
- ☰ 47.4. Creating Detector Crystals
- ☰ 47.5. Adding an F-18 Source
- ☰ 47.6. Configuring PET Physics
- ☰ 47.7. Recording Hits
- ☰ 47.8. Creating Singles
- ☰ 47.9. Applying Energy Blurring
- ☰ 47.10. Applying the PET Energy Window
- ☰ 47.11. Sorting Coincidences
- ☰ 47.12. Identifying True Coincidences
- ☰ 47.13. Identifying Scattered Coincidences
- ☰ 47.14. Creating Lines of Response
- ☰ 47.15. Saving PET Data
-
Comments
Please login to add a comment.
Don't have an account? Register now!